logo

products details

Created with Pixso. Casa Created with Pixso. prodotti Created with Pixso.
Limitatore di tensione della sottostazione
Created with Pixso.

Outdoor Brace-Type Surge Arrester HY5WBG-17/50 17kV Polymer Housing

Outdoor Brace-Type Surge Arrester HY5WBG-17/50 17kV Polymer Housing

MOQ: 1
prezzo: 1
Detail Information
Certificazione:
ISO9001
Modello n.:
HY5WBG-17/50
Tipo di installazione:
Scaricatori paralleli
Materiale:
Zno
Materiale abitativo:
Polimero
Valutazione di tensione:
17 kV
Corrente di scarica:
5kA
Tensione nominale:
17 chilovolt
Azionare la tensione continua:
13,6 kv
Tensione di CC massima:
25 chilovolt
Impulso minimo ripido:
57,5 kV
Impulso massimo di fulmini:
50 CHILOVOLT
Impulso di massima operazione:
42,5 kV
Corrente persistente:
0,5 mA
Corrente resistiva:
250 uA
Resistenza di piegamento:
1,6 kN
Evidenziare:

17kV polymer surge arrester

,

outdoor brace-type lightning arrester

,

HY5WBG-17/50 surge protector

Product Description
Outdoor Line Class Brace-Type Surge Arrester (HY5WBG-17/50)
Product Specifications
Attribute Value
Model NO. HY5WBG-17/50
Installation Parallel Arrester
Application Substation
Size Medium
Operation Voltage Low Voltage
Shape Cuboid
Material ZnO
Brand Yongde
Housing Color Grey
Housing Polymer
Voltage 17kv
Discharge Current 5ka
Transport Package Carton
Specification GB IEC
Trademark YongDe
Origin China
HS Code 85354000
Production Capacity 50,000 PCS/Year
Product Description
Brace-Type Surge Arrester
Operating Conditions
  • Suitable for both outdoor and indoor operation
  • Maximum altitude: 2000m
  • Power frequency range: 48Hz to 62Hz
  • Power frequency voltage must not exceed arrester's continuous operative voltage
  • Maximum earthquake intensity: 7 degree
  • Maximum wind speed: 35m/s
Construction Features and Operation Principle

The arrester features non-linear high-quality metal oxide varistor internals with a silicone rubber molded exterior.

Under normal conditions, the surge arrester maintains high resistance with only microampere current flow, ensuring no impact on equipment operation. During overvoltage events, the arrester switches to low resistance, conducting kilo-ampere current while maintaining voltage within safe limits to protect connected equipment.

Technical Specifications
Type Rated Voltage (KV) Operate Continuous Voltage (KV) Maximum DC 1 mA Reference Voltage (KV) Minimum Steep Impulse Residual Voltage (KV) Maximum Lightning Impulse Residual Voltage (KV) Maximum Operation Impulse Residual Voltage (KV) Persistent Current (MA) Resistive Current (UA) Bending Resistance (KN) Bending Broken (KN)
HY5WBG-17/50 17 13.6 25 57.5 50 42.5 0.5 250 1.6 4
Product Images
Outdoor Brace-Type Surge Arrester HY5WBG-17/50 17kV Polymer Housing 0 Outdoor Brace-Type Surge Arrester HY5WBG-17/50 17kV Polymer Housing 1 Outdoor Brace-Type Surge Arrester HY5WBG-17/50 17kV Polymer Housing 2 Outdoor Brace-Type Surge Arrester HY5WBG-17/50 17kV Polymer Housing 3 Outdoor Brace-Type Surge Arrester HY5WBG-17/50 17kV Polymer Housing 4 Outdoor Brace-Type Surge Arrester HY5WBG-17/50 17kV Polymer Housing 5 Outdoor Brace-Type Surge Arrester HY5WBG-17/50 17kV Polymer Housing 6 Outdoor Brace-Type Surge Arrester HY5WBG-17/50 17kV Polymer Housing 7